
Overview
The hydraulic reversing valve is used in Dual-line loop and short-loop systems, and it alternately sends the grease from the pump, to the two main pipes while accurately detecting the pressure and performing the switching operation. The pressure control valve and solenoid reversing valve are used in the end system. The pressure control valve is installed at the end of the piping, and when the set pressure is reached, it sends a signal to the control panel to stop the pump. The solenoid reversing valve KMV-1 receives the signal from the pressure control valve and alternately sends the grease to the two main pipes.
Specifications
Model | Pressure detecting method | Pipe Connection Diameter | Applicable pumps | Maximum operating pressure | Range of pressure setting | Voltage | Mass |
---|---|---|---|---|---|---|---|
KRV-22L | Mechanical | 4-Rc3/8 | KEP (Directly Mounted on Pump) |
20.6㎫ | 3.9~17.7㎫ | ― | 11.6㎏ |
KRV-32L | KSP820,KSPN1000,KEP | ― | 8.6㎏ | ||||
KMV-1 | Electrical | 2-Rc3/8 | Electric Pumps for End Type |
― | AC100V/110V(50㎐/60㎐)、 100V(60㎐) AC200V/220V(50㎐/60㎐)、 200V(60㎐) DC12V/DC24V |
9.9㎏ | |
KMV-2 | KSP820,KSPN1000,KEP | 3.9~17.7㎫ | ― | 10.2㎏ | |||
KCV-2ーD2 | ― | 4-Rc3/8 | Electric Pumps for End Type |
― | ― | 5.4㎏ |




PDF files of catalogues are available.